This section deals with problems related to the button controls on the Nuance PowerMic. For audio problems, see: Troubleshooting audio.
Common issues
In case of problems, check the following:
The Dragon PowerMic VMware/Omnissa Client Extension is correctly installed. For more information, see: Verifying the installation.
USB redirection is disabled:
You can't use USB redirection together with the Dragon PowerMic VMware/Omnissa Client Extension. USB redirection removes the audio device from the client and adds a virtual audio device on the server. For more information, see: Troubleshooting audio.
Verifying the installation
To verify that the Dragon PowerMic VMware/Omnissa Client Extension is correctly installed on the client end point, do the following:
On the client end point, open the Control Panel and select Programs and Features.
Check that Dragon PowerMic VMware/Omnissa Client Extension is listed.
Note
If the VMware/Omnissa session (
vmware-remotekms.exeprocess) was running during the installation of the Dragon PowerMic VMware/Omnissa Client Extension, the extension might not work properly.Go to
C:\Windows\System32and check that the following files exist:PowerMicClient.dllpmlog.dllPowerMicRDSClnt.dll
Go to
C:\Program Files\Common Files\Nuance\PowerMic(64-bitdllfiles) and check that the following files exist:PowerMicHid.dllpmlog.dll
Open the Registry Editor.
Browse for
HKEY_LOCAL_MACHINE\Software\Microsoft\Terminal Server Client\Default\AddIns\PMVMWCLand check the following:The
Namevalue points toC:\windows\system32\PowerMicRDSClnt.dll.The
PCoIP EnabledDWORDvalue is set to1.
Contacting support
The PowerMic SDK logging framework was changed; please contact support for instructions on how to enable logging for PowerMic SDK.
When you request support for VMware/Omnissa-related problems, please provide the following information:
- The troubleshooting steps you've already carried out and your results.
- Detailed steps describing how to reproduce the problem.
- The version number of the Dragon PowerMic VMware/Omnissa Client Extension.
- The type and operating system versions of thin clients used.
- The VMware/Omnissa Horizon version used on your system.
- The VMware/Omnissa client version used.
- The VMware/Omnissa server operating system.
- The guest operating system on the virtual machine.